Our top-of-the-line IFA Certified Welding Fume Extractors feature W3-certified filtration that removes 99% of hazardous welding fumes, ensuring a safer and healthier industrial workspace. Designed specifically for high-alloy steel processing and compliant with DIN EN ISO 21904 standards, these advanced extraction units deliver unmatched performance, energy efficiency, and global occupational safety.
Home » Welding Fume Exhaust Systems » Welding Fume Exhaust Systems » IFA Certified Welding Fume Extraction Units
TEKA
The VarioCube IFA is a high-capacity, stationary welding fume extractor certified for W3-class applications. Designed for industrial environments like shipyards...
TEKA
The StrongMaster is a high-efficiency mobile welding fume extractor designed for industrial use. IFA-certified and built for durability, it removes...
TEKA
The CareMaster Wall is a high performing, stationary, welding fume extractor. Constructed with a durable steel plate and finished with...
TEKA
The Filtoo Mobile Filter Unit is an efficient and adaptable air filtration solution, ideal for workshops, welding stations, and metalworking...
TEKA
The ZPF Central Suction and Filter Unit is a high-capacity filtration system designed for multi-station air extraction. With automatic filter...
+ 3 variants available
TEKA
The FilterCube 4H is a high-performance stationary filter unit designed for industrial metalworking applications. With over 99% filtration efficiency, it...
+ 4 variants available
TEKA
The CartMaster IFA for Wall Mounting is a stationary cartridge filter unit designed for IFA-certified welding fume extraction. With a...
+ 2 variants available
TEKA
The CartMaster Mobile Unit is a portable cartridge filter unit designed for IFA-certified welding fume extraction. With a high-capacity steel...
+ 2 variants available
TEKA
The CareMaster Mobile Extraction system is designed for effective filtration of smoke and dust generated during welding processes with non-alloy...
TEKA
The Filtoo is a compact, robust, and IFA W3-certified mobile extraction unit designed for diverse dust and fume applications, from...
+ 3 variants available
The Institute for Occupational Health and Safety of the German Social Accident Insurance (IFA) is a research and testing institute of accident insurance providers in Germany. IFA performs inspections and certification of extraction and filtration units in terms of their filtration capacity. The institute classifies the extraction and filtration units according to three classes of separation of welding fumes and approves them for use. IFA is based in Sankt Augustin near Bonn.
The Different Levels of IFA Certification
W1: W1 is the first and lowest level of separation of welding fumes. The class of separation of welding fumes provides information about the filtration capacity of the extraction and filtration system. The degree of separation must be at least 95% or more. Class W1 filters suitable for non-alloy and low-alloy steels.
W2: W2 is the second and medium level of separation of welding fumes. The class of separation of welding fumes provides information about the filtration capacity of the extraction and filtration system. With class W2 filters, the degree of separation must be greater than 99.5%. Class W2 filters are suitable for alloy steels containing nickel and chromium (5-30%).
W3: W3 is the third and highest level of separation of welding fumes. The class of separation of welding fumes provides information about the filtration capacity of the extraction and filtration system. Class W3 filters provide separation greater than 99.9%. These filters must be used for high-alloy steels that contain more than 30% of nickel and chromium.
W3 certification confirms that our extractors remove 99% of hazardous welding fumes, ensuring maximum protection against carcinogenic pollutants during high-alloy steel welding.
IFA certification guarantees that our systems meet strict international standards such as DIN EN ISO 21904 and TRGS 560, providing reliable air purification and safe recirculation of filtered air.
Industries like high-alloy steel manufacturing, welding fabrication, and industrial production rely on these certified units to maintain safe, compliant, and productive work environments.
Regular filter inspections, annual performance testing, and adherence to manufacturer guidelines are essential to maintain peak efficiency and extend the lifespan of your welding fume extractor.
Welding high-alloy steels and processes that generate carcinogenic fumes require the use of W3-certified units to ensure safe and effective pollutant removal.
OSHA does not issue its own certification for welding fume extraction systems. An IFA W3-certified exhaust system for welding fumes is engineered to meet or exceed OSHA’s stringent requirements. You can expect:
Thank you for your interest in Precision Welding Group and our family of brands! Whether you have questions about our industry-leading solutions, need more information on our products, or are looking for a custom solution tailored to your needs, we’re here to help.
Contact us today, our experts are ready to assist you!